KU 40-60W BUC SPEC V1.2

Product Parameters:

RF Specifications 40W 50W 60W
RF Frequency S: 14–14.5 GHz, E: 13.75–14.5 GHz, S&E(Software switching)
IF Frequency S: 950–1450 MHz, E: 950–1700 MHz
External Reference 10 MHz, 0±5 dBm
Saturated Output Power ≥46 dBm ≥47 dBm ≥47.8 dBm
Rated Output Power 46 dBm 47 dBm 47.8 dBm
Linear Output Power 43 dBm 44 dBm 44.8 dBm
Small Signal Gain 70 dB
Adjustable gain range 50-70 dB(step of 0.1 dB)
IMD3 at Linear Output Power ≤-25 dBc
Gain Variation (Fixed temperature) ≤1 dB p-p max./ 36 MHz, ≤3 dB p-p max./ 500 MHz, 4 dB p-p max./ 750 MHz
Gain Stability(Fixed Frequency) ≤3 dB p-p max.
Transmit noise power density ≤-76 dBm/Hz
Received noise power density ≤-156 dBm/Hz
Phase Noise ≤-75 dBc/Hz @1 KHz, ≤-85 dBc/Hz @10 KHz, ≤-95 dBc/Hz @100 KHz
Output Spurious ≤-55 dBc
Power Supply
Power Supply Range 18 ~ 55 VDC 22 ~ 55 VDC
Power Supply Draw  @Prated 180 W 210 W 240 W
Interfaces
RF Output Connector WR75 (Grooved)
RF Output VSWR 1.25:1
IF Input Connector N-type Female
IF Input VSWR 2:1
Redundancy Connector PT02E-12-14P
M&C Connector PT02E-12-14P, Support RS-485/Ethernet
LED Indicators Green LED ON : Functioning properly, Red LED ON: PLL alarm
Physical Parameters
Size 160*100*76 mm
Weight 1.5 Kg
Operating Temperature -40 ~ +70 ℃ -40 ~ +60 ℃
Humidity 0-100%
Altitude 0-7000 m (High operating temperature drops by 6 ℃ for every 1000 m while more than 3000 m)
Protection Level IP67